# AI verification proposal

A proposal built with the Proposal Explorer of the AI Verification Tech Map (https://trustbutveri.fyi/), from its records of 2026-11-24. Interactive version (uses current records): https://trustbutveri.fyi/explorer/?mechanisms=M-0020,M-0022&hide=weights,training
Data version: sha256:1878a72ad476d1e56b5bd4e53b47e876485b34f744d7c9bf7c28a0437e4a9915. This downloaded analysis preserves the exported text; the interactive link does not retrieve historical records.


How to read it: a claim is something one party wants to verify about another's AI hardware or software. A mechanism is a general technique for verifying claims; it is "aimed directly at" a claim when that is its direct purpose, and "supporting" when it contributes without being aimed directly at it. A claim's status says whether a mechanism in the proposal is aimed directly at it and is not excluded by the filters. That is a link on the map, not a verification result, so check that mechanism's development status, security evidence and findings. Definitions: https://trustbutveri.fyi/about/methodology/ (roles, properties and findings) and https://trustbutveri.fyi/about/readiness/ (development status).

## Filters

Filters apply to mechanisms only and describe the setting the proposal is for. A mechanism a filter rules out stays listed but does not count toward claim coverage. Selected implementations are filtered on their own record fields. Passing a filter does not establish that the assumptions hold in a deployment.

- **Not shown to the verifier: model weights, training data.** Removes mechanisms that show the asset to the verifier. Conditional or unspecified exposure stays with a note and needs checking against the privacy requirement. Model weights: the checked model’s parameters. Inputs and outputs: the requests a deployed model serves and its responses. Training data: what a model was trained on. Each mechanism’s exposure is the editors’ reading of its record: shown, depends on the design (kept, with a note), hidden, not involved, or unspecified for a selected implementation. Code and configuration are not covered yet.

24 of 25 mechanisms on the map pass these filters.

## Overview

One row per mechanism, read from its record. Open failures: critical / significant / minor. The last three columns are the editors’ reading of what the verifier sees. Findings are grouped as known weaknesses, scope limitations and open questions. Only known weaknesses count as failures. Counts are an inventory of published findings, not a risk score.

| Mechanism | Development status | Adversarial evaluation | Prover | Additional hardware | Open failures | Weights | Inputs and outputs | Training data |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| Remote detection of data centers | Proposed | Published analysis or argument | Adversarial | No additional hardware | 0 / 0 / 0 | not involved | not involved | not involved |
| Side-channel suppression for isolated facilities | Proposed | Published analysis or argument | Adversarial | Retrofit device | 0 / 0 / 0 | not involved | not involved | not involved |

## Claims

No claims chosen.

## Mechanisms

### Remote detection of data centers

Searching for large data centers, including undeclared ones, and estimating their power capacity without site access, from satellite imagery, heat signatures and public records. ([Remote detection of data centers](https://trustbutveri.fyi/mechanisms/remote-detection-of-data-centres/))

- Assessed as a mechanism (no implementation chosen).
- Development status: Proposed, assessed for finding undeclared data centers above an agreed compute threshold, not tracking known sites. [1][2][3][4][5]
- Security evidence: Published analysis or argument.
- Record sources: [1][2][3][4][5][6][7].
- Claims in this proposal: none of them.
- Threat model: adversarial prover. Additional hardware: no additional hardware. Prover cooperation: not required. Category: Remote & side-channel sensing.
- What the verifier sees. Model weights: not involved. Inputs and outputs: not involved. Training data: not involved. Works from outside the facility; it does not handle model data.

### Side-channel suppression for isolated facilities

Shielding, filtering, jamming and inspecting an AI facility to limit hidden physical communication around monitored network links. ([Side-channel suppression for isolated facilities](https://trustbutveri.fyi/mechanisms/side-channel-suppression/))

- Assessed as a mechanism (no implementation chosen).
- Development status: Proposed, assessed for bounding physical covert channels out of a verified enclosure. [8]
- Security evidence: Published analysis or argument.
- Record sources: [6][8][9][10][11][12][13][14][15].
- Claims in this proposal: none of them.
- Threat model: adversarial prover. Additional hardware: retrofit device. Prover cooperation: partial. Category: Off-chip devices & sensors.
- What the verifier sees. Model weights: not involved. Inputs and outputs: not involved. Training data: not involved. Shields and filters a facility; it does not handle model data.


## Properties

**Built for an adversarial prover**

- Remote detection of data centers
- Side-channel suppression for isolated facilities

**No new hardware needed**

- Remote detection of data centers


## Security evidence

The strongest published analysis or attack testing for each mechanism's assessed use.

- Remote detection of data centers: Published analysis or argument
- Side-channel suppression for isolated facilities: Published analysis or argument

## Limits

**Scope limitations**

- Facilities can be disguised or hidden (scope limitation, theoretical argument, in Remote detection of data centers; https://trustbutveri.fyi/mechanisms/remote-detection-of-data-centres/evidence/flaws/1/) [1]. Halstead and Larsen discuss two ways to hide a facility. One is to disguise it as a legitimate industrial site. The other is to build it underground, with cooling that avoids visible heat plumes. They note that the underground option requires bespoke engineering.
- Small sites may not be detectable (scope limitation, theoretical argument, in Remote detection of data centers; https://trustbutveri.fyi/mechanisms/remote-detection-of-data-centres/evidence/flaws/2/) [1][3]. Halstead and Larsen conclude that a sufficiently small covert project could not be ruled out with confidence. In their estimates, the chance of detection is lower for smaller sites. Krawec notes that small data centers in existing buildings may lack the distinctive features of large facilities.

  Related mechanism: Chip registries and manufacturing records (Proposed, not in the proposal). Accounts for chips from the fab onwards, which does not depend on a site being visible.
- Openings for airflow, power and optics weaken shielding (scope limitation, theoretical argument, in Side-channel suppression for isolated facilities; https://trustbutveri.fyi/mechanisms/side-channel-suppression/evidence/flaws/2/) [8]. Cankaya notes that keeping attenuation high while passing high-power airflow, cabling and optical links adds complexity beyond existing shielded-enclosure specifications.

**Open questions**

- Search for unknown sites is undemonstrated (open question, in Remote detection of data centers; https://trustbutveri.fyi/mechanisms/remote-detection-of-data-centres/evidence/flaws/3/) [3]. Krawec reports that telling data centers apart from other industrial facilities systematically is difficult. Automating detection would need large amounts of training imagery and a purpose-trained model. In Krawec’s words, automated data-center detection “remains primarily conceptual at present”.
- Supply-chain implants may evade inspection (open question, theoretical argument, in Side-channel suppression for isolated facilities; https://trustbutveri.fyi/mechanisms/side-channel-suppression/evidence/flaws/1/) [8]. Cankaya identifies malicious hardware embedded deep in purchased components as a residual risk that visual inspection and disassembly may not catch. He notes that radiographic examination under high-security standards could mitigate it.
- Inspection assumptions may not hold (open question, in Side-channel suppression for isolated facilities; https://trustbutveri.fyi/mechanisms/side-channel-suppression/evidence/flaws/3/) [8]. The design’s statistical argument assumes that visual or disassembly inspection catches every flaw that is present in a sampled unit. Cankaya is unsure whether destructive teardowns are defense-dominant or offense-dominant.

**Not yet demonstrated**

- Remote detection of data centers: Proposed, assessed for finding undeclared data centers above an agreed compute threshold, not tracking known sites
- Side-channel suppression for isolated facilities: Proposed, assessed for bounding physical covert channels out of a verified enclosure


## Possible additions

Mechanisms on the map, not in the proposal, that the records connect to a claim that is not linked or partly linked, an open failure or a dependency. Pointers, not recommendations: each brings its own development status and findings, and none is claimed to close a failure.

None found.



## Dependencies

**Blockers**

- Remote detection of data centers: Wide-area, automated detection of data centers is not yet practical and needs large training datasets. (coverage & hidden compute) [3]
- Remote detection of data centers: No measured detection or false-alarm rates for finding undeclared facilities have been published. (adversarial validation) [1][3]
- Remote detection of data centers: Recent high-resolution imagery is costly, is limited by weather and needs trained analysts. (access & governance) [3]
- Side-channel suppression for isolated facilities: No prototype enclosure for an AI rack or scalable unit has been built, measured for each channel class or red-teamed by a stated adversary. (adversarial validation) [8]
- Side-channel suppression for isolated facilities: Costs of filters, jamming and optical conversion at production scale are unvalidated, and TEMPEST-grade power-line filters are mostly made to order. (performance & compatibility) [8]


## What the verifier sees

- Model weights: not involved in Remote detection of data centers and Side-channel suppression for isolated facilities.
- Inputs and outputs: not involved in Remote detection of data centers and Side-channel suppression for isolated facilities.
- Training data: not involved in Remote detection of data centers and Side-channel suppression for isolated facilities.

## Implementations

- Remote detection of data centers: none on the map
- Side-channel suppression for isolated facilities: [AI 2040 inference-only verification stack](https://trustbutveri.fyi/implementations/ai-2040-inference-only-verification-plan/) (Proposed, proposed architecture); [Low-trust AI compute verification system overview](https://trustbutveri.fyi/implementations/low-trust-compute-verification-system-overview/) (Proposed, proposed architecture); [RAND secure inference data center (SIDC) design](https://trustbutveri.fyi/implementations/rand-secure-inference-data-centers/) (Proposed, proposed architecture)

## Sources

Numbered references used above; entries marked “Other record source” are additional sources on the assessed records.

1. Covert AI Projects, B. Halstead and T. Larsen (2026). https://ai-2040.com/supplements/covert-ai-projects
2. Verifying International Agreements on AI: Six Layers of Verification for Rules on Large-Scale AI Development and Deployment, M. Baker et al. (2025). https://www.rand.org/pubs/working_papers/WRA4077-1.html
3. Tracking Hyperscale AI Data Center Growth with Satellite Imagery, C. Krawec (2026). https://fas.org/publication/tracking-hyperscale/
4. Introducing the Frontier Data Centers Hub, Epoch AI (2025). https://epoch.ai/latest/introducing-the-frontier-data-centers-hub
5. AI Data Centers Documentation – Methodology, Epoch AI (2026). https://epoch.ai/data/data-centers-documentation/methodology
6. Hardware-Level Governance of AI Compute: A Feasibility Taxonomy for Regulatory Compliance and Treaty Verification, S. Ansari (2026). https://arxiv.org/abs/2604.04712
7. Limitations of Satellite Imagery Analysis for AI-Specific Data Centers, L. Heim and K. Pilz (2024). https://blog.heim.xyz/limitations-of-satellite-imagery/
8. Suppressing Side Channels in an Untrusted Data Center via Retrofitted Defenses, N. Cankaya (2026). https://techgov.intelligence.org/blog/suppressing-side-channels-in-an-untrusted-data-center-via-retrofitted-defenses
9. A System Overview for Near-Term, Low-Trust AI Compute Verification, N. Cankaya (2026). https://intelligence.org/wp-content/uploads/2026/06/A-system-overview-for-near-term-low-trust-AI-compute-verification.pdf
10. PowerHammer: Exfiltrating Data from Air-Gapped Computers through Power Lines, M. Guri et al. (2020). https://arxiv.org/abs/1804.04014
11. BarraCUDA: Edge GPUs do Leak DNN Weights, P. Horvath et al. (2025). https://www.usenix.org/conference/usenixsecurity25/presentation/horvath
12. Kraken: Higher-order EM Side-Channel Attacks on DNNs in Near and Far Field, P. Horvath et al. (2026). https://arxiv.org/abs/2603.02891
13. DeepTheft: Stealing DNN Model Architectures through Power Side Channel, Y. Gao et al. (2024). https://doi.org/10.1109/SP54263.2024.00250
14. Can governments quickly and cheaply slow AI training?, joshc (2026). https://www.alignmentforum.org/posts/Xzf3eMnhTko7AxnEy/can-governments-quickly-and-cheaply-slow-ai-training
15. RFD 006: Secure Enclosure (SCIF) for AI Clusters, AI Security Forum (2025). https://projects.aisecurity.forum/rfd/006/